Purpose & Method: The purpose of this study is the theoretical study on the durability standard of ground structures monitoring sensors. A survey on the durability criteria for construction monitoring sensors of domestic construction companies and the income tax implementation regulations, the standard years of contents such as buildings and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. Result: The durability criterion such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the ground structure, is 8 to 10 years. Conclusion: The actual durability analysis by comparing the reliability of various monitoring sensors installed in dams at home and abroad, As a result of comprehensive study on the loss and damage rate of the maintenance monitoring sensor installed in the tunnel, the proper durability period of the built-in type monitoring sensor such as domestic pore pressure meter and earth pressure meter installed in the structure or the ground is 5 to 8 years it seems reasonable.
연구목적 및 방법: 본 논문은 지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구로 국내 건설공사 발주기관의 건설 계측센서에 대한 내구연한 기준과 조달청의 건설계측 및 건설기계 관련 내용연수 기준을 분석하였다. 연구결과: 지반구조물에 설치되기 전 조달청에서 물품 자체로 구매하는 경사계와 변형률계 등의 내구연한 기준은 8년에서 10년을 제시하고 있다. 결론: 국내외 댐에 설치된 각종 계측센서의 신뢰성 비교를 통한 실제적인 내구연한 분석과 터널에 설치된 유지관리 계측센서의 경과연수에 대한 손망실율 등을 종합 검토한 결과 구조물이나 지반에 설치된 국내 간극수압계 및 토압계 등의 매립식 계측센서의 적정 내구연한은 5년에서 8년이 합리적인 것으로 판단된다.
References
  1. Kim, K.S. (2008). Advisory Report on Improvement of Durability and Years of use of Dam Instruments. Korea Water Resources Corporation, pp. 9-10.
  2. Korea Water Resources Corporation (2005). On-site Inspection and Evaluation Report of Dam Installation Monitoring System.
  3. Woo, J.T. (2013)."A study on trends analysis of the loss and damage ratio of tunnel maintenance monitoring sensors." Journal of Korean Tunnelling and Underground Space Association, Vol. 15, No. 1, pp. 25-31. 10.9711/KTAJ.2013.15.1.025
  4. Woo, J.T. (2018a). "A study on the regulation of durability standard of underground structures monitoring sensors." Journal of Korean Tunnelling and Underground Space Association, Vol. 20, No. 1, pp. 73-81.
  5. Woo, J.T. (2018b). "A study on the loss and damage ratio of railroad tunnel maintenance monitoring sensor," Journal of Korea Society of Disaster Information, Vol. 14, No. 3, pp. 262-270.
  6. Woo, J.T. (2019). "A study on the cause and improvement plans of construction monitoring sensors decline in durability," Journal of Korea Society of Disaster Information, Vol. 15, No. 1, pp. 28-38.
  7. Woo, J.T., Lee, K.I. (2012). "A study on establishment of measurement and analysis frequency of maintenance monitoring in tunnel." Journal of Korean Tunnelling and Underground Space Association, Vol. 14, No. 2, pp. 117-129. 10.9711/KTAJ.2012.14.2.117
  8. Woo, J.T., Lee, R.C. (2017). Theory and Practice of Construction Monitoring-underground Construction Facilities. CIR Publishing Co., pp. 92-94 (in Korean).
Information
  • Publisher :The Korean Society of Disaster Information
  • Publisher(Ko) :한국재난정보학회
  • Journal Title :Journal of the Society of Disaster Information
  • Journal Title(Ko) :한국재난정보학회논문집
  • Volume : 17
  • No :1
  • Pages :53-59