Purpose: Compared to general fires of the same size, underground parking lot fires are more likely to cause human and property damage and are not easy for firefighters to extinguish fire and save lives. This study attempted to find out how to secure the evacuation safety of parking lot users based on changes in the evacuation simulation behavior mode applied to evaluate the evacuation safety of the object. Method: Simulation for each CASE was performed using the Pathfinder program. Result: it was found that the higher the reference value, the higher the evacuation time, and Behavior showed an increase in time in SFPE mode rather than Steering mode. Priority was able to confirm an increase in time in priority designation rather than non-priority designation. Conclusion: The Required Safe Egress Time (RSET) for evaluating the evacuation safety of underground parking lots and the building evacuation design to ensure evacuation safety should be evaluated and reflected separately from Simulation's Behaviour Mode and Priority.
연구목적: 지하 주차장 화재는 동일 규모의 일반화재에 비하여 인명 및 재산피해의 우려가 크고 소방관의 소화활동 및 인명구조가 용이하지 않는 특성이 있다. 본 연구에서는 대상물의 피난안전성 평가를 위해 적용되는 피난 Simulation 행동모드의 변화를 기반으로 주차장 이용자의 피난안전성 확보방안에 대하여 알아보고자 하였다. 연구방법: Pathfinder 프로그램을 사용하여 CASE 별로 Simulation을 수행하였다. 연구결과: 기준값이 높아질수록 피난시간이 증가되는 것을 알 수 있었으며, Behavior는 Steering Mode 보다는 SFPE Mode에서 시간증가를 나타냈다. Priority는 무순위 지정보다는 우선순위 지정에서 시간증가를 확인할 수 있었다. 결론: 지하주차장의 피난안전성 평가을 위한 피난소요시간(RSET)과 피난안전성 확보의 건축물 피난설계는 Simulation의 Behavior Mode와 Priority을 구분하여 평가·반영되어야 한다.
References
  1. Gi, D.H. (2018). "Analysis on disaster information effect process to occupant behaviour: Focusing on relationship to egress time." Korean Journal of Construction Engineering and Management, Vol.19, No. 3, pp. 11-22.
  2. Im, S.H. (2021). "A study on the travel distance and exit width for securing efficient evacuation." Journal of The Korean Institute of Fire Science & Engineering, Vol. 35, No. 2, pp. 45-52. 10.7731/KIFSE.7e02e654
  3. Jeong, G.S. (2009). "Quantitative evaluation of escape safety considering extension of escape time by escape distance and escape barrier." Journal of The Korean Society of Hazard Mitigation, Vol. 9, No. 5, pp. 1-8.
  4. National Fire Agency (2019~2023). Fire Statistical Yearbook.
  5. National Fire Agency (2023). Standard Guidelines for Evaluation and Operation of Performance-oriented Designs such as Fire Fighting Facilities.
  6. Oh, S.C. (2022). "Analysis of evacuation time according to variation of evacuation stairs' width in large-scale goshiwons." The Journal of the Convergence on Culture Technology, Vol. 8, No. 5, pp. 641-651.
  7. Seo, D.G.(2021). " A study on the safety of evacuation according to evacuation delay time and fire door openness: Based on residence types." Fire Science and Engineering, Vol. 34, No. 2, pp. 156-165. 10.7731/KIFSE.0c0708c4
  8. Seon, Y.J. (2023). "Effect of the effective clear width of door in a modular classroom on evacuation time." Journal of The Korean Society of Hazard Mitigation, Vol. 23, No. 5, pp. 63-69. 10.9798/KOSHAM.2023.23.5.63
  9. The United States, International Building Code (IBC), Section 1004 Occupant Load, Table1004.1.2 Maximum Floor Area Allowances Per Occupant.
  10. Yoo, Y.H. (2009). Development of Fire Spread Prevention and Escape Safety Design Technique According to Standard Fire Model. 1415091720, Korea Institute of Construction Technology, Goyang, Gyeonggi-do, Korea, pp. 175-176.
Information
  • Publisher :The Korean Society of Disaster Information
  • Publisher(Ko) :한국재난정보학회
  • Journal Title :Journal of the Society of Disaster Information
  • Journal Title(Ko) :한국재난정보학회논문집
  • Volume : 20
  • No :2
  • Pages :284-292